dc.description.abstractPower flow data for the IEEE RELIABILITY TEST SYSTEM 1996. IEEE Reliability Test System Task Force of Applications of Probability Methods Subcommittee, "IEEE reliability test system-96," IEEE Transactions on Power Systems, Vol. 14, No. 3, Aug. 1999, pp. 1010-1020. See also (this network is three replicates of the RTS-79 system): IEEE Reliability Test System Task Force of the Applications of Probability Methods Subcommittee, "IEEE reliability test system," IEEE Transactions on Power Apparatus and Systems, Vol. 98, No. 6, Nov./Dec. 1979, pp. 2047-2054. Cost data is from Web site run by Georgia Tech Power Systems Control and Automation Laboratory: http://pscal.ece.gatech.edu/testsys/index.html Converted from data files on: http://www.ee.washington.edu/research/pstca/rts/pg_tcarts.htm Does not include optional DC link Bus voltage bounds from Matpower standard +/- 6% off nominal Reactive compensation at buses 106, 206, 306 is essential for feasibility due to line charging on branch 6-10. A shunt of 100 MVar is indicated in the RTS-79 paper. Matpower case file data provided by Clayton Barrows, Carleton Coffrin, and NICTA's Optisation Research Group. Copyright (c) 1999 The Institute of Electrical and Electronics Engineers (IEEE) Licensed under the Creative Commons Attribution 4.0 International license, http://creativecommons.org/licenses/by/4.0/en_US
dc.publisherIEEE PES Task Forceen_US
dc.subjectOptimizationen_US
dc.titlePGLib OPF Case 73 IEEE RTSen_US
dc.title.alternativeSmall Phase Angle Differenceen_US
dc.typeGrid Model Dataseten_US
grid.version1en_US
grid.publisher.urlhttps://github.com/power-grid-lib/pglib-opfen_US
grid.formatMatPoweren_US
grid.buses73en_US
grid.generators99en_US
grid.branches120en_US
grid.identifier.urlhttps://github.com/power-grid-lib/pglib-opf/blob/master/sad/pglib_opf_case73_ieee_rts__sad.m-
Appears in Collections:Transmission Steady State

File Description Size Format Export Browse
Matpower Data34.44 kBMATPOWER


User Comments

Average user rating

0.0 / 5

Rating breakdown

5
80% Complete (danger)
0%
4
80% Complete (danger)
0%
3
80% Complete (danger)
0%
2
80% Complete (danger)
0%
1
80% Complete (danger)
0%

Items in BetterGrids are protected by copyright, with all rights reserved, unless otherwise indicated.