Full metadata record
DC FieldValueLanguage
dc.contributor.authorDemetriou, Panayiotis-
dc.contributor.authorAsprou, Markos-
dc.contributor.authorQuiros-Tortos, Jairo-
dc.contributor.authorKyriakides, Elias-
dc.date.accessioned2017-07-26T14:49:26Z-
dc.date.available2017-07-26T14:49:26Z-
dc.date.issued2015-07-
dc.identifier.urihttp://item.bettergrids.org/handle/1001/282-
dc.description.abstractThe IEEE test bed systems available in the literature for steady-state studies are extended and modified to consider dynamic data for time-domain simulations. The dynamic parameters for a sixth order full machine model (i.e., machine, exciter, and governor) are defined for each generator in the IEEE test systems. Dynamic parameters are also determined for the condensers and motors. The dynamic parameters are based on typical dynamic models provided in Power system control and stability (P. M. Anderson, A. A. Fouad). More details about how the IEEE test systems are extended and modified to account for the dynamic parameters of typical dynamic models can be found in P. Demetriou, M. Asprou, J. Quirós-Tortós, and E. Kyriakides, “Dynamic IEEE Test Systems for Transient Analysis,” IEEE Systems Journal, Early access. The proposed dynamic test systems can be used for transient stability analysis purposes. In this website, the dynamic data for the IEEE test bed systems are fully provided in open access. The IEEE 39-bus modified test system contains 49 buses, 32 transmission lines, 24 transformers and 10 generators. It has 19 constant impedance loads totaling 6097.1 MW and 1408.9 MVAr. All the generators are equipped with an IEEE type-1 exciter and a simple turbine governor, except generator 39 which is an aggregation of a large number of generators and is considered not to have a governor.en_US
dc.publisherUniversity of Cyprusen_US
dc.subjectDynamicen_US
dc.titleDynamic IEEE 39-Bus Modified Test Systemen_US
dc.title.alternativePowerWorld Formaten_US
dc.typeGrid Model Dataset Referenceen_US
grid.publisher.urlhttp://www.kios.ucy.ac.cy/testsystems/en_US
grid.formatPowerWorlden_US
grid.buses49en_US
grid.generators10en_US
grid.loads19en_US
grid.branches32en_US
grid.identifier.urlhttp://www.kios.ucy.ac.cy/testsystems/index.php/dynamic-ieee-test-systems/ieee-39-bus-modified-test-system-
grid.identifier.urlhttp://ieeexplore.ieee.org/document/7151773/-
Appears in Collections:Transmission Dynamic



User Comments

Average user rating

0.0 / 5

Rating breakdown

5
80% Complete (danger)
0%
4
80% Complete (danger)
0%
3
80% Complete (danger)
0%
2
80% Complete (danger)
0%
1
80% Complete (danger)
0%

Items in BetterGrids are protected by copyright, with all rights reserved, unless otherwise indicated.